Thank you that you have chosen the G-Systems Engineering Ltd CO₂ Controller product.
The CO₂ ventilation controller is a multifunctional device designed to manage climate and air quality in ventilated rooms. It offers the following key features:
-
Fan speed control for ventilated rooms, allowing regulation of an exhaust fan or both intake and exhaust fans, as well as controlled dosing of CO₂ gas.
-
Lighting control , including on/off switching and continuous dimming of connected lighting systems.
-
Programmable sockets that can be controlled based on sensor values or timers, for example for heating, cooling, humidification, dehumidification, or operation of a CO₂ valve.
The primary purpose of the CO₂ Controller is to maintain optimal room temperature and humidity levels, both during the day and at night, with independent target values for each period. In addition, the controller creates a slight negative pressure in the room to prevent odors from escaping into surrounding areas.
The warranty is valid only if:
-
A warranty card issued by the seller with stamp, signature, and sales date is included, or
-
A purchase receipt or invoice with the printed serial number is available, or
-
An electronic registration has been made at http://g-systems.eu/warranty/
If none of these documents are available, please contact your point of sale.
Operating voltage: 230V / 50Hz
Maximum permissible plug and cable ratings, country-dependent:
-
Type F (Schuko, DE): max. 16A
-
Type E (FR): max. 16A
-
Type J (CH): max. 13A
-
Type G (UK): max. 13A
Output load capacities, resistive load, cos φ = 1:
-
Output 1 (variable): min. 200W / max. 10A (2300W)
-
Output 2 (variable): min. 200W / max. 10A (2300W)
-
Output 3: max. 10A (2300W)
-
Output 4: max. 10A (2300W)
Each pair of outputs shares a common 16A supply line:
Outputs 1 and 3
are supplied via one 16A input, and
Outputs 2 and 4
are supplied via a second 16A input.
The
combined load
of each output pair must
not exceed 16A
.
Control signal outputs:
-
Intake fan: 0–10V or PWM
-
Exhaust fan: 0–10V or PWM
-
Light control: 0–10V
Install the device using the supplied mounting bracket on a solid, non-combustible surface (e.g., concrete or masonry).
Installation on combustible materials, including wood, plastic, cardboard, or similar, is not permitted.
Ensure that the installation location provides adequate ventilation to allow effective dissipation of heat generated during operation.
Do not install the device in confined spaces, enclosed cabinets, or areas with insufficient air circulation.
⚠️ Warning:
Improper installation or insufficient ventilation may cause overheating, resulting in malfunction, damage to the device, or risk of fire.
You can navigate through the menu using the rotary push knob :
-
Turn clockwise to move to the next option or to increase a setpoint.
-
Turn counterclockwise to decrease a setpoint.
-
Press the knob to confirm a selection or to save a value.
-
Socket 1 (Variable)
-
Socket 2 (Variable)
-
Socket 3
-
Socket 4
-
Navigation knob
-
Screen
-
EC intake fan
-
Power cable 1 (left side)
-
CO2 sensor connector
-
Lighting
-
Temperature sensor connector
-
Power cable 2 (right side)
-
EC exhaust fan
Display of Actual Values
This screen shows the current system values:
-
CO₂ cycle active
-
Countdown time of the CO₂ function
-
Day/Night indicator (also shown by a dark background – see figure below)
-
Day counter
-
Current time
-
CO₂ dosing
-
CO₂ distribution
-
CO₂ target value reached
-
CO₂ ventilation
-
Fan overrun time (standstill time)
-
Temperature display – temperature sensor
-
Temperature display – CO₂ sensor
-
Humidity
-
CO₂ concentration
Display of Outputs
This screen shows the current statuses of the outputs:
-
Light intensity
-
Supply fan speed
-
Exhaust fan speed
-
Output 1 – Manual ON
-
Output 2 – Manual OFF
-
Output 3 – Automatic ON
-
Output 4 – Automatic OFF
Display of Measured Maximum and Minimum Values and Alarm Messages (Events)
This section displays current actual values as well as their recorded limits and alarms:
-
Temperature (gas sensor)
-
Humidity (gas sensor)
-
Temperature (temperature sensor)
-
CO₂ value
-
Current actual display
-
Minimum recorded values
-
Maximum recorded values
Alarm(s):
This screen appears in red when a value is outside the configured and activated minimum or maximum limit – or when the CO₂ bottle is empty.
-
Press the knob once to acknowledge the alarm.
-
If the alarm remains active after acknowledgment, a red border will appear on the screen. The device can still be used normally.
-
The red border disappears automatically once all values return to the acceptable range.
Note on the CO₂ bottle alarm:
If an alarm is triggered due to an empty CO₂ bottle, the CO₂ function is deactivated. After replacing the bottle, the function must be manually reactivated.
If you want to acknowledge the alarm without replacing the bottle, manually switch the CO₂ function off and on again.
Main Menu
To access the settings menu, press the rotary/push knob once
Menu Items
-
Return to main screen
-
Main menu display (current position)
-
CO₂ settings
-
Ventilation settings
-
Lighting settings
-
Output 1 – Settings
-
Output 2 – Settings
-
Output 3 – Settings
-
Output 4 – Settings
-
Device settings (submenu)
The currently selected option is highlighted with a larger icon.
Press the knob to confirm your selection and enter the corresponding submenu.
Navigate to item 3: CO₂ Settings and press the knob to open the menu.
The following options are available in this menu:
-
CO₂ Menu Display (You are here)
-
Enable or disable CO₂ dosing during daytime
-
Set CO₂ values
-
Set CO₂ gas distribution time
-
Start conditions for CO₂ dosing
-
Stop or exhaust conditions for CO₂
-
Fan overrun time
-
Room settings and dosing parameters
-
Minimum speed setting for for CO₂ time
Navigate to the desired option and confirm your selection by pressing the knob.
Note on item 2:
Press the knob to toggle CO₂ dosing on or off during the daytime.
-
Set CO₂ Value (current position)
-
CO₂ Target Value – Enter the desired setpoint in ppm (e.g., 2000 ppm).
-
CO₂ Hysteresis – Defines the difference between the switch-on and switch-off thresholds.
Example – Hysteresis:
With a CO₂ target value of 2000 ppm and a hysteresis of −200 ppm, the controller will begin dosing only when the CO₂ level drops below 1800 ppm. Dosing continues until the level reaches 2000 ppm again.
Press the knob again to save the values.
Then return to the CO₂ menu and select the next option: 4. CO₂ Gas Distribution Time
After dosing, a so-called distribution time follows, during which the CO₂ disperses evenly throughout the room before any potential follow-up dosing. This time should be set according to the room size to allow the CO₂ level to stabilize properly.
-
CO₂ Distribution Time
-
Time format in minutes : seconds – e.g., 01:30 (1 minute 30 seconds)
-
CO₂ Dosing Repetitions – Specifies how many times the dosing/distribution cycle is repeated
After the set number of repetitions, CO₂ dosing stops.
If the CO₂ level remains below the target value and no further dosing occurs, the alarm “CO₂ bottle empty” is automatically triggered, and the CO₂ mode is deactivated.
In this menu, you define the start conditions for CO₂ dosing. Multiple conditions can be activated— all activated conditions must be met simultaneously for the dosing process to begin. At least one condition must be enabled.
-
Start CO₂ Time – Overview and activation of the start menu
-
Temperature – Threshold value for the condition
-
Enable Temperature – Toggle ON/OFF for the temperature condition
-
Humidity – Threshold value for the condition
-
Enable Humidity – Toggle ON/OFF for the humidity condition
-
Time (minutes : seconds) – Time-based start condition
-
Enable Time – Toggle ON/OFF for the time condition
Example:
If both temperature and humidity are activated, the dosing process will only start when
both conditions are met simultaneously
.
In this menu, you define the stop conditions for CO₂ dosing. When any of the activated conditions is met, CO₂ injection will stop and the exhaust phase will begin. At least one condition must be activated.
-
Start of Ventilation Time – Overview and activation of this menu
-
Temperature – Upper temperature threshold
-
Enable Temperature Condition – Toggle ON/OFF for temperature control
-
Humidity – Upper humidity limit
-
Enable Humidity Condition – Toggle ON/OFF for humidity control
-
Time (Minutes : Seconds) – Time-based stop condition
-
Enable Time Condition – Toggle ON/OFF for time control
Example:
If the temperature exceeds the limit, humidity rises above the set value, or the countdown reaches zero, the CO₂ dosing process is interrupted and the exhaust fans start automatically.
After the exhaust phase ends (Start of Ventilation Time), the fan continues spinning for a short period due to mechanical inertia before coming to a complete stop.
1. Stop Fan – Overview of the stop behavior
2. Fan Run-Off Time – Adjustable time in seconds
Depending on the fan's size and type, it may take a few seconds to come to a complete stop.
The run-off time defined here determines how long the system waits after the exhaust phase ends before allowing a new CO₂ dosing cycle to begin.
-
Room Settings – Overview of room configuration
-
Room Volume (m³) – Enter the room’s volume in cubic meters
-
Gas Flow Rate (liters/minute) – Set the CO₂ supply rate according to your system
Calculation and Installation Notes:
-
Room Volume: Calculate the volume as
Length × Width × Height
-
Flow Rate: Enter the CO₂ system’s gas flow rate in liters per minute (l/min)
-
Unit Conversion – SCFH to l/min:
1 SCFH = 0.471 l/min
Installation Tip:
Ideally, mount the CO₂ hose behind a recirculating fan.
This ensures the heavier CO₂ gas distributes evenly across the room.
Effective air circulation is critical for accurate CO₂ readings.
Minimum speed setting for for CO₂ time
This menu allows you to configure the minimum speed of the exhaust fan during the active CO₂ function (daytime operation).
-
Minimum CO₂ Fan Speed – Overview of this setting
-
Minimum Speed – Adjustable value in percent (%)
Recommendation:
Ideally, this value should be set to 0% (fan off) to avoid unnecessary loss of CO₂ gas.
However, if odor control is required and a slight negative pressure must be maintained in the room, a minimum fan speed can be set — typically between 10% and 30%.
To configure additional ventilation parameters, return to the main menu and select:
CO₂ Dosing Test Procedure
-
Set CO₂ minimum fan speed to 0%
-
Start the CO₂ dosing process
On the main screen (Part 1), the following will be displayed:
-
Step 6 : CO₂ dosing starts (with countdown)
-
Step 7 : CO₂ distribution begins (also with countdown)
After the distribution phase, the CO₂ target value minus the hysteresis must be reached -
Step 8 : “CO₂ Level Reached” should light up
Troubleshooting Guide
1. CO₂ level not reached
-
Check if the distribution time is set long enough
-
If CO₂ rises too slowly, increase distribution time
2. CO₂ level is too low, immediate re-dosing starts
-
Increase the gas flow rate at the CO₂ valve
-
Alternatively: Reduce Gas Flow Rate (l/min) in the regulator settings
-
Or adjust the Room Volume (m³) :
-
Smaller volume = shorter gassing time
-
Larger volume = longer gassing time
-
3. CO₂ level too high
-
Decrease the gas flow rate at the valve
-
Or increase the Flow Rate (l/min) in the regulator — depending on whether the CO₂ system is under- or over-delivering
This menu allows you to configure the parameters for room ventilation:
-
Ventilation Menu – Main overview
-
Temperature Settings – Configure ventilation based on temperature thresholds
-
Humidity Settings – Configure ventilation based on humidity thresholds
-
Minimum and Maximum Fan Speeds – Set the operational range of the fan
-
Negative Pressure Setting – Maintain a slight negative-pressure for odor or air control
Note:
These settings are only active during the
daytime
when
CO₂ dosing is deactivated
or the
“CO₂ bottle empty”
alarm is triggered.
During
nighttime operation
, ventilation is always regulated according to these settings.
Temperature Settings
In this menu, you can define the desired daytime and nighttime temperature setpoints, as well as the temperature hysteresis range.
-
Temperature Settings – Overview of this menu
-
Day Temperature – Target temperature during daytime operation
-
Night Temperature – Target temperature during nighttime operation
-
Temperature Hysteresis – Range used for smooth fan speed modulation
Adjustment Guide
Set the desired day and night temperatures here, along with the positive hysteresis value.
Example:
If the day temperature is set to 24.0 °C and the hysteresis is +2.0 °C :
-
Up to 24.0 °C , the fans remain off or operate at minimum speed
-
Between 24.0 °C and 26.0 °C , fan speed increases linearly
-
At 26.0 °C and above , fans operate at the maximum configured speed
In this menu, you can define the desired humidity setpoints for daytime and nighttime operation, as well as the hysteresis range for smooth fan control.
-
Humidity Settings – Overview
-
Daytime Humidity – Target relative humidity during the day
-
Nighttime Humidity – Target relative humidity at night
-
Humidity Hysteresis – Tolerance range for gradual fan speed adjustment
Adjustment Notes
Set the desired daytime and nighttime relative humidity values along with the positive hysteresis .
Example:
If the target is 60% RH (Relative Humidity) and the hysteresis is set to +10% RH :
-
Up to 60% RH : Fans remain off or run at minimum speed
-
Between 60% and 70% RH : Fan speed increases gradually
-
From 70% RH and above : Fans operate at maximum speed
Important:
The higher deviation — whether from the temperature or humidity setpoint — determines the fan speed.
In this menu, you define the limits for fan speeds that must not be exceeded or undercut – separately for daytime and nighttime operation.
-
Max. & Min. Fan Speeds – Overview
-
Minimum Fan Speed (Day)
-
Minimum Fan Speed (Night)
-
Maximum Fan Speed (Day)
-
Maximum Fan Speed (Night)
-
Intake Fan Behavior – Off or set to minimum
-
Exhaust Fan Cut-Off Temperature
Explanation:
Settings 2–5 define the
permitted range
of fan speeds based on time of day.
Each value sets the
operating window
for speed modulation.
When both temperature and humidity are below their setpoints, this setting controls how the intake fan responds:
-
Off – Intake fan is completely shut off
-
On – Intake fan runs at the exhaust fan’s speed minus the defined pressure differential
If the room temperature drops below this value, the exhaust fan is automatically switched off to prevent the room from overcooling.
In this menu, you can define the pressure difference between the intake and exhaust fans to maintain a constant negative pressure inside the room.
-
Negative Pressure Menu – Overview
-
Negative Pressure Setting – Pressure difference in percent (%)
Purpose
To prevent
unwanted odors
from escaping the room, the
exhaust fan
must extract
more air
than the intake fan supplies.
This creates a slight
negative pressure
, ensuring that potentially contaminated air stays inside.
Practical Setup Tip
-
Run both intake and exhaust fans at maximum speed .
-
Check airflow behavior, e.g., by observing air movement through a keyhole or door gap :
-
Air should be drawn into the room — not pushed out.
-
-
Adjust the negative pressure setting until there’s a slight inward draft , but not so strong that it makes the door hard to open.
To configure the lighting settings, return to the main menu and select: ➡️ 5. Lighting Settings
Main Menu → Lighting Settings
-
Lighting Settings Menu – Overview
-
Enable/Disable Lighting – Turn the lighting function on or off
-
Lighting Schedule – Define on/off times
-
Maximum and Minimum Brightness – Set brightness limits
-
Sunrise and Sunset Simulation – Enable soft transitions in light intensity
Installation Note
Lighting is controlled via a signal output and should be connected to your lighting system using the port labeled “Light.”
Adapters & Accessories
A range of adapter cables and connectors is available at: www.growshopping.com or from your local distributor.
Lighting Connection
To connect the lighting system, the following pins are required:
-
Pin 2: GND (Ground)
-
Pin 4: Signal (Control signal output)
-
Lighting Schedule Menu – Overview
-
Lighting ON Time – Set the switch-on time
-
Lighting OFF Time – Set the switch-off time
Note:
Set the lighting start and end times in hours and minutes .
-
Light Intensity Menu – Overview
-
Start CO₂ Time – Temperature (for reference only)
-
Stop CO₂ Time / Start Exhaust – Temperature (for reference only)
-
Start Dimming Temperature – Temperature at which dimming begins
-
Stop Dimming Temperature – Temperature at which dimming ends
-
Maximum Light Intensity
-
Minimum Light Intensity
-
Lighting Re-Enable Temperature
-
Lighting Cut-Off Temperature
Function Description:
-
Items 2 and 3 (marked red in the UI) are for reference only .
-
Start Dimming Temperature (4):
This is the point where lamps begin to dim in response to increasing heat.
→ As long as the measured temperature remains below this value , lamps operate at maximum intensity (6) . -
Stop Dimming Temperature (5):
The point at which dimming ends. Once this temperature is reached, the system sets the minimum light intensity (7) . -
The minimum intensity remains active until the room reaches the lighting cut-off temperature (9) .
-
If the temperature continues to rise and overheating persists , the system fully switches off the lights at the cut-off point (9).
-
Lights will only turn back on once the temperature falls below the re-enable temperature (8) .
Adjustment Note:
Set the
minimum light intensity (Option 7)
to a level where the lamps
continue operating reliably even at the lowest dimming level
.
→ They should
not turn off completely
, unless this behavior is
explicitly intended
.
This menu allows you to activate and configure soft dimming for sunrise and sunset transitions.
-
Sunrise & Sunset Menu – Overview
-
Sunrise Duration – Duration in minutes
-
Sunset Duration – Duration in minutes
-
Enable Sunrise Simulation
-
Enable Sunset Simulation
Example – Sunrise (10 minutes):
-
At the lighting ON time , the system starts the sunrise simulation .
-
The lights begin at the minimum intensity .
-
Over the next 10 minutes , the brightness gradually ramps up to the maximum intensity .
Example – Sunset (10 minutes):
-
10 minutes before the lighting OFF time , the sunset simulation begins.
-
The brightness dims smoothly from the current level down to the minimum intensity .
-
After the countdown, lighting is fully dimmed.
To configure the switching logic for Output 1, return to the main menu and select: 6. Output 1 – Settings
-
Output 1 – Menu
-
Intake Fan (AC)
-
Exhaust Fan (AC)
-
Manual Switching
-
CO₂ / Temperature / Humidity / Light Sensor (Gas Sensor)
-
Temperature Sensor
-
Timer (Time Switch)
-
CO₂ Solenoid Valve
You are now configuring Exit 1
This output can operate in one of the following two modes:
-
Variable Control
via phase-angle control (only suitable for AC fans ) → options 2–3 -
Relay-based ON/OFF switching
for all other devices → options 4–8
The currently active function is visually indicated with a green frame around its icon in the menu.
Important Notes for Variable Outputs (Exit 1 & 2):
-
Connect a minimum load of 200 W to ensure stable operation.
-
Ensure that the fans truly stop at 0% .
→ Some small fans with large suppression coils may continue spinning even when set to 0%.
How to Activate a Function:
-
Select the desired function (e.g. fan, sensor, relay).
-
Activate it using the toggle switch.
-
Only one function per output can be active at a time.
Manual Switching
-
Enable this mode to control the output manually.
-
Use the provided toggle to switch the output ON or OFF .
-
(Note: No graphical representation is available for this mode.)
-
Gas Sensor Menu – Overview
-
Enable/Disable Sensor – Turn the sensor module on or off
-
Heating – Activate output when temperature is too low
-
Cooling – Activate output when temperature is too high
-
Humidifying – Activate output when humidity is too low
-
Dehumidifying – Activate output when humidity is too high
Usage Instructions:
-
Activate the sensor using option 2.
-
Then select one of the four control functions :
-
Heating (3)
-
Cooling (4)
-
Humidifying (5)
-
Dehumidifying (6)
-
Each function uses the sensor’s readings to control the output relay accordingly.
-
Heating Menu – Overview
-
Enable/Disable Heating – Turn the heating output ON or OFF
-
Daytime Temperature – Set target temperature for daytime
-
Nighttime Temperature – Set target temperature for nighttime
-
Temperature Hysteresis – Define the switching buffer range (negative value for heating)
Configuration:
Set a target temperature for both day and night , along with a negative hysteresis value.
Example – Heating:
-
Target Temperature: 24.0 °C
-
Hysteresis: –2.0 °C
➡ Heating turns ON at <22.0 °C
➡ Heating turns OFF at >24.0 °C
-
Select the temperature sensor to be used.
Configuration:
The settings and behavior are identical to the gas sensor when used with the “Heating” function.
→ See the Heating section for configuration instructions regarding:
-
Day/Night target temperatures
-
Negative hysteresis
-
On/off switching behavior based on measured temperature
-
Timer Menu – Overview
-
Enable/Disable Timer
-
Step(s) – Program step number (up to 24 steps)
-
Start Time (Hours/Minutes)
-
End Time (Hours/Minutes)
-
End Time (Seconds)
-
Enable/Disable Step
How to Use the Timer:
-
Enable the timer function via option 2.
-
Use the rotary knob to scroll through up to 24 programmable steps .
➤ The currently selected step is indicated by two bars on the left and right. -
Press the knob to enter edit mode and set the time:
-
→ Start Hour
-
→ Start Minute
-
→ End Hour
-
→ End Minute
-
→ End Second
-
-
Enable the step once it’s configured, then move to the next step if needed.
If you want to use the CO₂ solenoid valve on this output, select this function and enable it using the toggle switch .
Outputs 3 and 4 operate based on the same principle as Outputs 1 and 2, with the following key differences:
-
❌ No variable control (no phase-angle regulation)
-
✅ Relay switching only (ON/OFF control)
In this submenu, you can configure all core system parameters of the device, such as time, backlight, alarm behavior, and sensor offset.
-
Device Settings Menu – Overview
-
Time and Date – Set system clock and calendar
-
Light Sensor – Automatic brightness adjustment via ambient light
-
Screen (Display) – Adjust brightness, contrast, and screen timeout
-
Alarms – Enable/disable alarms, set volume and alert behavior
-
Sensor Signal Offset – Fine-tune sensor readings
-
Output Signals – Configure output signal behavior
-
Reset to Factory Settings – Restore all settings to default state
-
Reset Min/Max Values – Clear all stored extreme measurement values
-
Time and Date Menu – Overview
-
Date – Set in the order: Day → Month → Year
-
Time – Set in: Hours → Minutes
-
Day Counter – Tracks usage days
Explanations:
-
Date:
Set the current date using the sequence: Day → Month → Year -
Time:
Enter the current time in hours and minutes -
Day Counter:
-
On the first day of use, the counter starts at 1
-
It automatically increases by +1 at 23:59:59 each day
-
⚠️ Important:
If the device is powered off at that time , the counter will not increment
-
In this menu, you configure the light intensity detection feature of the gas sensor to allow automatic switching between day and night modes.
-
Light Sensor Menu – Overview
-
Light Intensity – Currently measured brightness (in %)
-
Switch Delay – Delay time before switching occurs
-
Switch Threshold – Light intensity level at which the system switches modes
How It Works
-
First , turn on your lighting at the minimum intensity setting .
-
The Light Intensity value will show the current brightness detected by the gas sensor.
-
Ideally, when lighting is on, this value should be close to 100% , which the controller automatically interprets as “Day Mode.”
-
Switch Delay:
This setting prevents immediate switching when there is a brief change in lighting (e.g., when the door opens).
-
When the switch threshold is exceeded, the switch timer starts.
-
Only if the brightness remains stable for the entire delay period, the system switches between Day and Night modes.
Switch Threshold:
Here you define the light intensity level (in %) that triggers the transition between Day Mode and Night Mode .
In this menu, you can configure the display behavior of the device.
-
Display Menu – Overview
-
On / Automatic – Display operating mode
-
Timeout Duration – Time before automatic screen shutdown
-
Brightness – Adjust screen brightness
Recommendation:
To prolong the display’s lifespan , it is recommended to set the screen to “Automatic” mode when not in use.
How Automatic Mode Works:
-
In Option 3: Timeout Duration , you define how long the display stays on without user interaction .
-
After the set time passes:
-
The display dims for 10 seconds
-
Then it turns off completely
-
➡️ To wake up the screen , simply rotate or press the control knob.
Brightness:
-
Under Option 4 , set the screen brightness according to your ambient lighting conditions or personal preference .
In this menu, you can define which sensor values will trigger alarms .
-
Alarms Menu – Overview
-
Temperature (Gas Sensor)
-
Humidity (Gas Sensor)
-
CO₂ (Gas Sensor)
-
Temperature Sensor (External Sensor)
Alarms
How to Set Alarms:
-
Select the sensor parameter you wish to monitor
→ e.g. "Temperature (Gas Sensor)" -
In the corresponding submenu , you can configure:
-
Threshold values (upper/lower limits)
-
Hysteresis (optional)
-
Alarm behavior (e.g., acoustic, visual, both)
-
Important Note:
Alarms are crucial for identifying critical conditions early , such as:
-
Overheating
-
Excessive CO₂ concentration
-
Humidity levels outside the safe range
-
Temperature (Gas Sensor) – Menu Overview
-
Maximum Temperature – Threshold for overtemperature alarm
-
Enable/Disable Maximum Temperature Alarm
-
Minimum Temperature – Threshold for undertemperature alarm
-
Enable/Disable Minimum Temperature Alarm
Procedure – Setting Up Temperature Alarms
-
Set the desired threshold value at which you want to be alerted.
→ Example: 2. Maximum Temperature = 35.0 °C
-
Enable the alarm function under Option 3 .
What Happens When an Alarm Is Triggered?
-
If the measured value exceeds or falls below the set limit, a red alarm screen will appear on the device.
-
If Wi-Fi is enabled and you are using the GSE smartphone app , a push notification will be sent to your phone.
Repeat the same steps for:
-
4. Minimum Temperature – e.g., for frost protection
-
3. Humidity (Gas Sensor)
-
4. CO₂ (Gas Sensor)
-
5. External Temperature Sensor
Sensor Offset Adjustment
In this menu, you can manually correct displayed sensor readings by adjusting the values shown on the screen.
-
Offset Menu – Overview
-
Temperature Offset (Gas Sensor)
-
Humidity Offset (Gas Sensor)
-
CO₂ Offset (Gas Sensor)
-
Temperature Offset (External Sensor)
How to Use:
If the values shown on the screen differ from a reference device , you can enter a positive or negative offset here to match the display to your reference.
Important Note:
This function does
not perform an actual calibration
of the sensor.
It only adjusts the
displayed value
– the internal measurement logic and sensor readings remain unchanged.
Example:
-
Your reference thermometer shows: 22.5 °C
-
The display shows: 21.5 °C
➡ Enter a +1.0 °C offset under Temperature Offset
In this menu, you configure the signal output types and minimum speeds for EC fans as well as the lighting control output .
-
Output Signal Menu – Overview
-
EC Intake Fan – Signal Type
-
EC Intake Fan – Minimum Speed
-
EC Exhaust Fan – Signal Type
-
EC Exhaust Fan – Minimum Speed
-
Lighting – Signal Type
Configuring the EC Intake Fan
-
In Option 2 , select the desired signal type :
-
0–10 V (analog) or
-
PWM (pulse-width modulation)
-
-
Go to the Ventilation → Min/Max Speeds menu and set the maximum speed of the intake fan to 1% .
-
Check on the main screen (Section 2) whether the 1% value is actually applied.
Test Run:
-
Observe whether the EC intake fan starts spinning at 1% speed.
-
If the fan does not rotate or just shakes slightly, increase
Option 3 – EC Intake Fan Minimum Speed by +1% .
Repeat this process until the fan reliably starts spinning on its own when switched on.
Configuring the EC Exhaust Fan
Repeat the same procedure for:
-
Option 4 – EC Exhaust Fan Signal Type
-
Option 5 – EC Exhaust Fan Minimum Speed
Tip:
Some EC fans require a
higher minimum speed
to run stably.
→ Depending on the model, this is usually between
5% and 15%
.
Configure Lighting Signal
To configure the lighting control output:
-
Go to Option 6: Lighting – Signal Type
-
Select the desired output type:
-
0–10 V (analog)
-
or PWM (pulse-width modulation)
-
This function restores the device to its original factory state.
→ All custom settings will be erased and replaced with default values, as if starting the device for the first time after purchase.
-
Factory Reset Menu – Overview
-
Select Reset Option: YES / NO
-
Current software Version installed
Procedure:
-
Select "YES" to initiate the reset process.
-
A black confirmation screen will appear with a second safety prompt .
-
Confirm the reset by selecting the green checkmark symbol ✅ or cancel by selecting the red cross symbol ❌
The controller will then restart , and all data will be reset to factory defaults.
Warning:
This action
cannot be undone
.
All personal settings, timers, sensor values, and calibrations will be
permanently deleted
.
This function clears all previously stored minimum and maximum readings of the measured values (e.g. temperature, humidity, CO₂) from Main Screen – Section 3.
Procedure:
Follow the same steps as for the “Reset to Factory Settings” function:
-
Navigate to this menu
-
Select “YES” to confirm
-
A confirmation prompt will appear
-
Confirm the reset by selecting the green checkmark symbol ✅ or cancel by selecting the red cross symbol ❌
Once confirmed, all recorded
extreme values
will be deleted.
→ The controller will automatically
begin recording new min/max values
from that point onward.